updating configuration
This commit is contained in:
@@ -1,8 +1,22 @@
|
||||
# ----------- User configutaion ------------------
|
||||
substitutions:
|
||||
devicename: domofon
|
||||
upper_devicename: Domofon
|
||||
pin_cold: D1
|
||||
init_cold: '210.29'
|
||||
pin_hot: D2
|
||||
init_hot: '109.74'
|
||||
water_open_pin: D5
|
||||
water_close_pin: D3
|
||||
ultrasonic_echo_pin: D6
|
||||
ultrasonic_trig_pin: D7
|
||||
# ----------- /User configutaion ------------------
|
||||
|
||||
# Need to turn off logging because senseair uses uart and have conflicts with logging
|
||||
logger:
|
||||
|
||||
esphome:
|
||||
name: watercontrol
|
||||
name: $devicename
|
||||
platform: ESP8266
|
||||
board: d1_mini
|
||||
|
||||
@@ -12,7 +26,7 @@ wifi:
|
||||
|
||||
# Enable fallback hotspot (captive portal) in case wifi connection fails
|
||||
ap:
|
||||
ssid: "Watercontrol Fallback Hotspot"
|
||||
ssid: "$upper_devicename Fallback Hotspot"
|
||||
password: !secret esphome_captive_pass
|
||||
|
||||
captive_portal:
|
||||
@@ -24,7 +38,6 @@ api:
|
||||
ota:
|
||||
password: !secret esphome_pass
|
||||
|
||||
|
||||
globals:
|
||||
- id: water_state
|
||||
type: bool
|
||||
@@ -33,17 +46,17 @@ globals:
|
||||
- id: counter_cold_value
|
||||
type: float
|
||||
restore_value: yes
|
||||
initial_value: '210.29'
|
||||
initial_value: $init_cold
|
||||
- id: counter_hot_value
|
||||
type: float
|
||||
restore_value: yes
|
||||
initial_value: '109.74'
|
||||
initial_value: $init_hot
|
||||
|
||||
binary_sensor:
|
||||
- platform: gpio
|
||||
name: pulse_cold
|
||||
pin:
|
||||
number: D1
|
||||
number: $pin_cold
|
||||
mode: INPUT_PULLUP
|
||||
filters:
|
||||
- delayed_off: 100ms
|
||||
@@ -54,7 +67,7 @@ binary_sensor:
|
||||
- platform: gpio
|
||||
name: pulse_hot
|
||||
pin:
|
||||
number: D2
|
||||
number: $pin_hot
|
||||
mode: INPUT_PULLUP
|
||||
filters:
|
||||
- delayed_off: 100ms
|
||||
@@ -64,7 +77,7 @@ binary_sensor:
|
||||
|
||||
sensor:
|
||||
- platform: uptime
|
||||
name: "Watercontrol Uptime"
|
||||
name: "$upper_devicename Uptime"
|
||||
|
||||
- platform: template
|
||||
name: "counter_hot"
|
||||
@@ -79,22 +92,22 @@ sensor:
|
||||
update_interval: 60s
|
||||
|
||||
- platform: ultrasonic
|
||||
trigger_pin: D7
|
||||
echo_pin: D6
|
||||
trigger_pin: $ultrasonic_trig_pin
|
||||
echo_pin: $ultrasonic_echo_pin
|
||||
name: "Toilet Distance"
|
||||
update_interval: 5s
|
||||
|
||||
switch:
|
||||
- platform: gpio
|
||||
pin:
|
||||
number: D5
|
||||
number: $water_open_pin
|
||||
inverted: yes
|
||||
id: water_open
|
||||
interlock: [water_close]
|
||||
|
||||
- platform: gpio
|
||||
pin:
|
||||
number: D3
|
||||
number: $water_close_pin
|
||||
inverted: yes
|
||||
id: water_close
|
||||
interlock: [water_open]
|
||||
|
||||