# Need to turn off logging because senseair uses uart and have conflicts with logging
logger:
esphome:
name: watercontrol
platform: ESP8266
board: d1_mini
wifi:
ssid: !secret wifi_24_name
password: !secret wifi_24_pass
# Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: "Watercontrol Fallback Hotspot"
password: !secret esphome_captive_pass
captive_portal:
# Enable Home Assistant API
api:
password: !secret esphome_pass
ota:
password: !secret esphome_pass
globals:
- id: water_state
type: bool
restore_value: yes
initial_value: 'true'
- id: cold_value
type: float
restore_value: yes
initial_value: '210.29'
- id: hot_value
type: float
restore_value: yes
initial_value: '109.74'
binary_sensor:
- platform: gpio
name: pulse_cold
pin:
number: D1
mode: INPUT_PULLUP
filters:
- delayed_off: 100ms
on_press:
then:
- lambda: 'id(cold_value) += 0.01;'
- platform: gpio
name: pulse_hot
pin:
number: D2
mode: INPUT_PULLUP
filters:
- delayed_off: 100ms
on_press:
then:
- lambda: 'id(hot_value) += 0.01;'
sensor:
- platform: uptime
name: "Watercontrol Uptime"
- platform: template
name: "counter hot"
lambda: |-
return id(hot_value);
update_interval: 60s
- platform: template
name: "counter cold"
lambda: |-
return id(cold_value);
update_interval: 60s
- platform: ultrasonic
trigger_pin: D7
echo_pin: D6
name: "Toilet Distance"
update_interval: 5s
switch:
- platform: gpio
pin:
number: D5
inverted: yes
id: water_open
interlock: [water_close]
- platform: gpio
pin:
number: D3
inverted: yes
id: water_close
interlock: [water_open]
- platform: template
name: "Water valve"
icon: "mdi:cup-water"
lambda: |-
return id(water_state);
turn_on_action:
- switch.turn_on: water_open
- delay: 5s
- switch.turn_off: water_open
- lambda: 'id(water_state) = true;'
turn_off_action:
- switch.turn_on: water_close
- delay: 5s
- switch.turn_off: water_close
- lambda: 'id(water_state) = false;'